How to Plan Factory Ventilation, Fans, Air Handling Units, Ductwork and Heat Recovery
We explain how factory airflow is worked out, how to pick fan types, where air handling units and heat recovery fit, and why ducts, dampers and diffusers matter, plus checks for new and used equipment.
In this article · 9 sections
- What is the difference between general ventilation and local extraction?
- How do you work out the required airflow?
- Which fan type suits which job?
- When do you need an air handling unit, heat recovery or fan filter units?
- Why do ducts, diffusers, dampers and silencers matter as much as the fan?
- Where do air curtains and air purifiers fill the gaps?
- New or used ventilation equipment?
- Why does a nearby supplier and service team help with factory ventilation?
- Frequently Asked Questions
Ventilating a factory is not just installing fans. It means planning how much air to move, where to take it from and where to supply it, while controlling energy use. Fans, air handling units, ducts, dampers, diffusers and heat recovery units are parts of one system. This guide explains the questions to ask and the role each component plays.
What is the difference between general ventilation and local extraction?
Local extraction captures a contaminant where it is generated, such as a hood above a welding bench or a dust collector attached to a machine. General ventilation replaces the air across the whole hall, removing heat, humidity and any diluted contaminants left behind. A well designed plant uses both; neither one substitutes for the other.
Dense contaminants such as welding fume, oil mist and process dust should be solved at source first, and we cover that in our guide to dust and fume collection systems. This article focuses on the ventilation and air filtration system components that keep the rest of the hall comfortable and the air quality acceptable.
How do you work out the required airflow?
Airflow is not set by a single formula but by the largest of several needs. Heat released by machines and people, process humidity, the amount of contaminant that must be diluted and the number of occupants are each assessed separately. Whichever criterion demands the most air becomes the basis of the design.
In practice a mechanical engineer combines hall volume, heat sources, outdoor design conditions and the occupational health requirements that apply locally. Picking a fan from a rough air-change rule tends to lead to either poor ventilation or wasted energy. A fan bought before the calculation is the most expensive mistake, because ductwork and electrical supply are then built around it.
- Establish the heat load of the hall and summer and winter outdoor conditions.
- List contaminants and moisture sources not handled by local extraction.
- Calculate the fresh air required for the number of occupants.
- Take the highest value as design airflow and balance extract with supply.
Which fan type suits which job?
Fan selection depends on system resistance as much as airflow, meaning the pressure drop created by ducts, filters and dampers. In short or ductless applications axial fans move large volumes with little energy. Long ducted systems with filters need higher-pressure fans. Where the fan curve meets the system curve decides it.
- An axial fan is an economical choice for wall and window exhaust with low system resistance.
- A roof exhaust fan extracts directly at ceiling level, where hot air collects, and is common in large single-storey halls.
- A jet fan pushes air towards the extraction point in car parks and tunnels without the need for ductwork.
- A smoke extraction fan is built to run at high temperature for a defined period during a fire; it should not be confused with an ordinary ventilation fan and must be designed into the fire strategy.
When do you need an air handling unit, heat recovery or fan filter units?
If outdoor air must be heated, cooled, filtered or humidity controlled, a plain fan is not enough. An air handling unit groups these functions in one casing. A heat recovery unit transfers energy from exhaust air to incoming air, and fan filter units deliver filtered air from the ceiling in clean areas.
When choosing an air handling unit, look at coil capacity, filter class, fan type and service access to the casing. A fresh air and heat recovery unit cuts heating load in halls that take in fresh air continuously through winter, though oily or dusty exhaust air will foul the exchanger and has to be allowed for. A fan filter unit is installed modularly in the ceiling of clean areas such as electronics assembly, pharmaceutical and food packing rooms.
Why do ducts, diffusers, dampers and silencers matter as much as the fan?
The distribution system is what delivers air from the fan to the right place, at the right velocity and quietly. Undersized or heavily bent ductwork spends fan power on pressure loss. The wrong diffuser blows uncomfortable draughts onto workers. Dampers balance airflow between branches, while silencers stop fan noise spreading into occupied areas.
The section, material and airtightness of ventilation ducts and fittings shape long-term energy use. A grille and diffuser determines how air spreads through the space, and long-throw diffusers are preferred in high-ceilinged halls. A damper and fire damper do two different jobs: balancing dampers set the flow, while fire dampers close the duct between fire compartments. A silencer is the most practical way to avoid noise complaints at exhaust points near offices or homes.
Where do air curtains and air purifiers fill the gaps?
Frequently opened loading doors and small rooms that need individual treatment are the weak points of a central system. An air curtain limits the cold or warm air, insects and dust entering through an open doorway. An air purifier filters and recirculates air in the room it stands in, without any connection to ductwork.
An air curtain is sized to the width and height of the door; one that does not cover the full opening will not perform as expected. An air purifier is a useful add-on in metrology rooms, control rooms or small workshops that are hard to connect to the central system, but since it supplies no fresh air it does not replace ventilation.
New or used ventilation equipment?
Simple components such as fans, ducts and grilles can be sensible used purchases, provided they match the design airflow and pressure. With air handling and heat recovery units, the condition of coils, exchangers and insulation is decisive. For smoke extraction fans and fire dampers, new and certified equipment is the safer route.
- Read airflow, pressure and motor power from a used fan's nameplate and ask for its fan curve.
- Listen to it running for bearing noise, impeller imbalance and vibration.
- On an air handling unit, inspect coils for corrosion, the drain pan for deposits and casing seals.
- For fire safety equipment, ask whether test and conformity documents are available.
Why does a nearby supplier and service team help with factory ventilation?
A factory ventilation system works when fans, ducts, filters and controls are matched on site. Airflow measurement, duct sealing and balancing happen during commissioning, and filter changes and fan maintenance recur afterwards. Having the supplier and service team close to the plant therefore simplifies both installation and operation.
For plants in Bursa, a hub for automotive, textile and metal industries, ventilation and air filtration systems in Bursa is a list worth checking. Processes that generate dust, such as welding, grinding or woodworking, need extraction at source in addition to general ventilation; for that, dust collection systems in Bursa can be reviewed separately.
Frequently Asked Questions
Is a roof fan alone enough for a factory?
Without a controlled path for make-up air to replace what is extracted, a roof fan cannot reach its rated flow and draughts form at the doors. Extract and supply should be planned together.
Is heat recovery suitable for every plant?
It usually pays off in heated or cooled halls with a constant fresh air intake. If exhaust air carries heavy oil, dust or corrosive vapour, the exchanger type and cleaning access need particular attention.
Can a smoke extraction fan be used for everyday ventilation?
Some systems are designed to do both, but that decision belongs to the qualified designer preparing the fire strategy. Assigning an arbitrary fan to smoke extraction is not safe.
How can ventilation noise be reduced?
Correctly sized ducts with low air velocity, a fan running near its efficient point, flexible connectors and duct silencers together lower noise noticeably.