Industrial Cable Types, Which Power, Control, Data, Solar and Fire-Resistant Cable for Which Job

Where NYY, N2XY, NYM, H05VV-F, MV cable, overhead conductors, LiYCY, Cat6, fibre, drag chain, FE180 and solar cable are used, plus termination materials, storage and common mistakes.

In this article · 7 sections
  1. Where do you start when choosing industrial cable?
  2. Which power cable is used where?
  3. How do you choose control, signal and data cables?
  4. When do you need flexible, special or fire-resistant cable?
  5. How do you choose installation materials and store cable?
  6. What are the most common cable selection mistakes?
  7. Frequently Asked Questions

Choosing industrial cable is about much more than cross-section. Of two cables with the same size, one can run underground for years while the other breaks within weeks in a moving drag chain. This guide explains where power, medium voltage, overhead, control, data, solar, fire-resistant and special cables are used, plus installation materials, storage and common mistakes.

Where do you start when choosing industrial cable?

Start with where and how the cable will work. Voltage level, current, run length, installation environment, whether it moves, temperature, contact with oil or chemicals and the required behaviour in a fire must all be known first. Sizing the conductor and its protection is a job for a qualified electrical engineer.

When browsing cables, reading the cable code correctly helps a great deal; the code usually describes the conductor material, insulation and sheath type and often the flexibility. We cover factory-scale planning in our article on electrical infrastructure for a new factory. The table below shows which cable group to look at first for each application. Note that the type codes used below follow the European designation system common in Turkey.

ApplicationCable group to check first
Panel feeders, underground and ducted power runsPower cable
Transformer and distribution connectionsMedium voltage cable
Pole-to-pole distribution linesOverhead line conductor
Sensors, push buttons, valves and measurement signalsControl and signal cable
Networks, cameras and fieldbusData and fibre optic cable
Solar panel DC stringsSolar cable
Emergency and fire systemsFire-resistant cable
Moving machinery, welding, pumps, high temperatureSpecial purpose cable

Which power cable is used where?

For low voltage power cables, the key differences are insulation material, conductor material and flexibility. PVC-insulated cables are common in general installations, while XLPE insulation is preferred where a higher operating temperature is needed. Aluminium conductors save weight and cost, but the termination materials must be suitable for aluminium.

In the power cables group, NYY underground cable is widely used in the ground, in ducts and on trays. For the same job, the XLPE-insulated N2XY XLPE low voltage cable allows a higher conductor temperature. On long feeder runs, NAYY aluminium conductor cable can be considered, provided aluminium-rated lugs and terminals are used. For fixed wiring inside buildings, NYM installation cable is used, and for panel and conduit wiring, NYA and NYAF single core wire. Where an appliance or machine connection moves, choose H05VV-F flexible cable instead of fixed installation cable.

On the medium voltage side, choosing a medium voltage cable is a design task. The choice between N2XSY copper MV cable and NA2XSY aluminium MV cable depends on current, distance and connection equipment. An MV cable termination and joint must be selected as a kit matching cable type, size and voltage level, and installed by trained personnel. Distribution lines use an overhead line conductor: an AAC conductor is bare aluminium, an ACSR conductor has a steel core that suits longer spans, and an aerial bundled cable is insulated and bundled, which makes it popular in built-up areas.

How do you choose control, signal and data cables?

With control and signal cables, the main issue is electrical noise. A signal cable without a screen running near inverters, motors or welders picks up interference, so readings fluctuate and sensors trigger falsely. Screening, cable routing and how the screen is earthed should be planned together with the cable choice.

In the control and signal cables group, use LiYCY shielded control cable in noisy environments and LiYY unshielded control cable in simple control circuits with little interference. Analogue measurement lines call for instrumentation cable. A servo and encoder cable must follow the construction specified by the drive and motor manufacturer, since a different core layout causes faults. A thermocouple compensation cable must match the thermocouple type, otherwise readings drift.

For data and fibre optic cables, Cat6 and Cat7 Ethernet cable serves office and site networks, while fibre optic cable stands out over long distances and in noisy environments. In fibre links, the fibre patch cord and pigtail must match the connector type. On machine and automation networks, choose Profibus and industrial Ethernet cable rather than office cable, because it is designed for vibration, oil and interference.

When do you need flexible, special or fire-resistant cable?

Standard cable is not enough where the cable flexes constantly, meets oil or chemicals, runs hot, or must keep working during a fire. Under these conditions the wrong cable soon cracks, breaks its conductors or fails in a fire. State the operating conditions clearly to the cable supplier before ordering.

In the special purpose cables group, continuously moving machines such as CNC and robots need drag chain cable; fixed installation cable soon breaks in a chain. Outdoors, on construction sites and on mobile equipment, H07RN-F rubber cable is used; for welding machine leads, welding cable; for borehole and submersible pumps, submersible pump cable; and around ovens and heaters, silicone and high temperature cable.

Choosing fire resistant cables involves two separate needs. Emergency lighting and alarm circuits that must keep working for a set time during a fire use FE180 fire alarm cable and FE180 fire resistant power cable. Enclosed and crowded spaces, where low smoke and limited toxic gas are required, use halogen free cable. In demanding conditions, mineral insulated cable may be considered. For solar installations, the solar cables group offers UV and weather resistant H1Z2Z2-K solar DC cable, the MC4 connector and branch for panel connections and solar extension cable; do not mate connectors whose compatibility the manufacturer has not confirmed.

How do you choose installation materials and store cable?

A cable's life is often decided at its termination. A lug that does not match the conductor size, a crimp made with the wrong tool or a gland that does not fit the cable diameter leads to heating, loosening and moisture ingress. In storage, open ends and sunlight damage cable before use.

In the cable connection and installation materials group, a cable lug and ferrule must suit the conductor size and material and be crimped with the correct tool. A cable gland is chosen for the cable's outer diameter and the required ingress protection. Inside panels, a terminal block and connector must cover the conductor size range. Use sleeving and heat shrink tube for insulation and marking, cable tie and spiral wrap for bundling, and cable duct and cable tray for routing.

  • Store cable on its drum in a dry, shaded area.
  • Seal cut ends to keep moisture out.
  • Follow the direction arrow when rolling a drum.
  • Do not force bends in very cold weather when the sheath has stiffened.
  • Keep different cable types labelled; once the print wears off, types get mixed up.

What are the most common cable selection mistakes?

The most common mistake is choosing cable by cross-section alone. If environment, movement and interference are ignored, even a correctly sized cable fails early. The second is not choosing termination materials with the same care as the cable. The third is running power and signal cables together in one tray without separation.

  1. Using fixed installation cable in a moving application
  2. Running unshielded signal cable next to an inverter output
  3. Using copper-only lugs on aluminium conductors
  4. Connecting compensation cable that does not match the thermocouple type
  5. Using cable without UV resistance outdoors
  6. Laying power and signal cables in the same tray without separation

If you want to know how cable is built layer by layer, our article on cable production line machinery explains the process from conductor to sheath.

Frequently Asked Questions

What is the difference between NYY and N2XY?

Both are low voltage power cables. NYY has PVC insulation and N2XY has XLPE insulation. XLPE allows a higher operating temperature; the choice depends on the design conditions.

How should a cable screen be earthed?

That depends on the system design and the equipment manufacturer's guidance. Incorrect earthing can increase noise rather than reduce it, so consult the system designer.

How long can cable be stored on a drum?

Cable kept dry, shaded and with sealed ends stays usable for a long time. Before installation, check the sheath for cracks and deformation.

Can ordinary cable be used instead of solar cable?

It is not recommended. Solar cable is designed for DC voltage, UV exposure and outdoor conditions. The sheath of ordinary cable can degrade in sunlight over time.